Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
3.
Article in English | IMSEAR | ID: sea-159841

ABSTRACT

Objecu've: On-site evaluation of laboratories with standard checklist is a first step to promote effective and consistent supervision. The present study was carried out to evaluate the impact of the RNTCP- Intermediate Reference Laboratory External Quality Assessment- On-Site Evaluation visits on quality of sputum smear microscopy services of Gujarat, India. Data of three IRL-EQA-OSE visit rounds, carried out between January 2005 and December 2010 are presented here. Materiaf and Methods: Within the Revised National Tuberculosis Control Programme EQA framework, the IRL, Ahmedabad visited all Gujarat District Tuberculosis Centres, and evaluated their sputum smear microscopy services. The study covered a cohort of 29 DTCs during each of the three IRL-EQA-OSE visits. The authors focused on section III of Annexure A to study and analyse the said impact. In order to convert qualitative data into quantitative one, the authors denoted a score of 1 to "Acceptable" (No Error) remark and 0 to "Not-Acceptable" (Error) one. Results.' Alarger degree of improvement was noted in Standard Operating Procedure practices, Disinfection practices, and Internal Quality Control practices. Many DTCs did not retrain their laboratory staff in EQA methodology. The Gujarat DTCs achieved an overall score of (8201957) 86% during the initial OSE visits which consistently improved to (842/957) 88% and (885/957) 92% during the two follow-up OSE visits along with sustenance and improvement in many important laboratory parameters. Conclusion' The co-sponsoring organisation (IRL) recognises the challenges and therefore, is committed to supporting state-level implementation of EQA through additional training, technical assistance to districts, and improving this technical guidance. By periodic IRL. EQA-OSE visits, sputum smear microscopy services can be sustained and improved at field level.

4.
Article in English | IMSEAR | ID: sea-146891

ABSTRACT

Objective: To assess the proficiency of Senior TB Laboratory Supervisors (STLSs) and district level Laboratory Technicians (LTs) in sputum smear microscopy. Method: Intermediate Reference Laboratory (IRL), Ahmedabad had manufactured and validated Proficiency Panel Testing slides from sputum samples, made On Site Evaluation (OSE) visits of District TB Centres (DTCs) in two rounds, and conducted Proficiency Panel Testing of STLSs & DTC-LTs from January 2005 to June 2009. Results: High level of concordance in Z-N smear grading was found between Microbiologist and district laboratory staff. DTC readers reported overall consistency level of more than 98% in Z-N grade agreement during both the IRL, EQA, OSE visits. The tendency to over-grade the panel slides was much higher (more than 22%) as compared to under-grade (less than 2%) them in “correct slides”. High False Positive (HFP) error was not observed in the present study. Conclusion: Laboratory supervisor’s proficiency can be quickly assessed by Proficiency Panel Testing, under multi-level quality assurance network system of sputum smear microscopy in public health programmes like the RNTCP. Proficiency Panel Testing is highly replicable and reproducible tool for quick and reliable assessment of proficiency of the staff and it can be made more effective by raising the proportion of lower grade positive slides in panel set of each reader. DTC readers’ overall agreement level of more than 98% in Z-N grade suggests high level of precision and excellent consistency during both the IRL, EQA, OSE rounds. It is concluded that even for a large network of sputum smear microscopy centres under public health programmes like the RNTCP in order to take corrective action, Proficiency Panel Testing can be effectively used for quick identification of suboptimal- technical performance of the supervisory staff.

5.
Indian J Chest Dis Allied Sci ; 2004 Apr-Jun; 46(2): 125-8
Article in English | IMSEAR | ID: sea-30440

ABSTRACT

Angioimmunoblastic lymphadenopathy (AILD) is a rare condition, which is difficult to diagnose as it mimics tuberculosis or lymphoma both clinically and radiologically. A case of AILD with pulmonary involvement that was initially mistaken for tuberculosis on fine needle aspiration cytology and put on antituberculous treatment for three months, is presented here. The case was subsequently diagnosed to lymph node biopsy as one of AILD.


Subject(s)
Adult , Diagnosis, Differential , Humans , Hypoproteinemia/complications , Immunoblastic Lymphadenopathy/complications , Lung/pathology , Male , Tuberculosis, Pulmonary/diagnosis
SELECTION OF CITATIONS